Thrust Washing Wear Test

 

             Material
                   Rotating Sample   - Toughmet CX105

                  Stationary              - AISI 8620 Case
                                                 Carburized to 60 to 64 RC, surface coated with Metalife system

             Surface Roughness

                   Toughmet             - 31.6 to 37.4 u" Ra
                   Steel                      - 10.7 to 12.6 u" Ra

             Contact Area               - .2 sq. inches

             Velocity                       - 100 ft/min

             Load                             - 20 lbs, 100 psi

             PV Level                      - 10,000        

             Lubricant
                    Test l                      - Dry
                    Test 2                    - Mobilith SHC 460 grease

             Temperature                - 72ºF at the start

             Test Duration               - 20 hrs.        

Test Procedure

Journal Bearing PV Limit Test
   The test procedure was as follows:
    -    Wipe excess liquid from the Metalife coated steel samples
    -    Measure surface roughness, in u" Ra, on the Form Talysurf
    -    Install the bearing and shaft in the LFW 5 (Falex #5) Journal bearing test apparatus
    -    Apply load and start the shaft rotating at 100 ft/min
    -    Run for 30 minutes and measure friction force and bearing temperatures

 

Click here for product information.

 

Hit Counter


Last modified: 02/14/07