The PV limit for the combination was 31,000 in the unlubricated condition and 360,000 PV for
         the lubricated condition. The dry friction coefficient was .29 and the lubricated value was .02.
         The maximum temperature was 420ºF for the unlubricated condition and 213ºF for the lubricated
         condition.

         There was slight damage to the bearing and shaft in the unlubricated condition and little to no
         damage in the lubricated condition.        

         Table II shows the results of the thrust washer wear tests. The friction coefficient in the
         unlubricated condition was .13 and in the lubricated condition was .08. The maximum
         temperature was 475ºF for the unlubricated condition and 313ºF for the lubrication test.

         The wear rate for the unlubricated condition was 3.2 mg/hr and less than < 0.1 mg/hr for the
         lubricated test. Slight damage was noted on the unlubricated sample surface and very little
         damage was obvious on the lubricated sample.

         Conclusions

         The overall results for the Metalife coated samples show a considerable increase in PV limit
         when compared to previous tests run on uncoated samples. Similar comparisons to uncoated
         wear tests indicate that the wear rate was reduced significantly when coated with the metalife
         system.

         If you have any questions, please do not hesitate to call me.

         Sincerely,

       
         Salvadore J. Calabrese
         Research Specialist

 

Click here for product information.

 

Hit Counter


Last modified: 02/14/07